9 products found
BUHLMANN Diagnostics Corp Products
-
Calprotectin (BÜHLMANN fCAL® assays)
Calprotectin is an incredibly valuable tool. The calprotectin technology platforms offered by BÜHLMANN range from the gold standard ELISA assay, BÜHLMANN fCAL® ELISA, to the lateral flow rapid test, Quantum Blue®, to the new IBDoc® self test and to the automated random access BÜHLMANN fCAL® turbo assay. This portfolio provides all possible applications for measuring calprotectin from the subject’s home test to the high throughput lab. BÜHLMANN is continuously evolving IBD solutions to meet customers’ needs.
-
Quantum Blue - Calprotectin Lateral Flow Assay
The Quantum Blue® Calprotectin lateral flow assay combines the ease and speed of lateral flow technology (using a highly specific monoclonal antibody to calprotectin), with full quantification by means of a small, telephone sized reading device. The Quantum Blue® Reader analyzes the signal intensity from the test and control line to give a quantitative value and is standardized with the BÜHLMANN fCAL® ...
-
Autoimmunity
-
Quantum Blue - Model MRP8/14 - Serum Calprotectin- sCAL Kit
BÜHLMANN MRP8/14 ELISA and Quantum Blue® MRP8/14 are for Research Use Only. Not for use in diagnostic procedures in the US. MRP8/14 Assays (myeloid-related protein) (aka serum calprotectin, sCAL, ...
-
BUHLMANN - Model CIC-C1q ELISA - Assay
CIC-C1q ELISA is FDA 510(k) cleared (K012576). For in vitro Diagnostic Use. Health Canada Licence: 106172. Circulating Immune Complexes (CIC) ELISA, (Complement C1q, Antigen, Antiserum, Control). The BUHLMANN CIC-C1Q ELISA is intended for the quantitative in vitro diagnostic determination of circulating immune complexes (CIC) in serum and plasma of patients with various autoimmune and other CIC-related ...
-
BUHLMANN - Model Anti-C1q - Autoantibodies ELISA
Anti-C1q Autoantibodies ELISA is for Research Use Only. Not for use in diagnostic procedures in the US. The BÜHLMANN anti-C1q Autoantibodies ELISA is intended for the quantitative determination of anti-C1q autoantibodies in human serum or plasma. Our anti-C1q autoantibodies ELISA can be used as a simple research tool for lupus related ...
-
Cellular Allergy
-
Flow CAST - Cellular Allergy Stimulation Test
The Flow CAST®(Cellular Allergy Stimulation Test) is intended for the determination of basophil activation in whole blood samples by flow cytometry. Our unique marker combination – CCR3 and CD63 – combines the simple gating properties for basophil detection by CCR3 with the solid application of the proven activation marker CD63 in one. Thanks to its easy protocol and smart marker combination the first results can be obtained within one ...
-
CAST - Elisa Kit
CAST® ELISA is for Research Use Only. Not for use in diagnostic procedures. The BÜHLMANN CAST® ELISA is intended for the quantitative determination of sulfidoleukotrienes (sLT) produced by isolated leukocytes upon contact with specific antigens. CAST® assays are available in combination with >160 standardized and validated ...
-
Flow CAST - Kinase Inhibition Assays
Flow CAST® Support in Drug Development: Inhibition of Basophil Activation is a Surrogate Biomarker for the Activity of Kinase ...
-
Clinical Chemistry
-
BUHLMANN - Model ACE Kinetic - Angiotensin Converting Enzyme
In vivo, ACE catalyzes the conversion of Angiotensin I to Angiotensin II and inactivates bradykinin during regulating blood pressure via Renin-Angiotensin-System. Elevated levels of serum ACE have been measured in patients suffering from various disorders. They often indicate a poor prognosis or rapid progression of the disease. Elevated serum ACE levels are reported in granulomatous-inflammatory diseases such as Sarcoidosis and Mixed-Connective-Tissue ...
-
BÜHLMANN - ACE High Sensitive Assay
The BÜHLMANN ACE high sensitive assay is designed to quantify reproducibility increased ACE activity in CSF samples. ACE activity measurement in diluted serum samples is possible as well. The assay shows a detection limit of 1 U/L and can be applied either on microtiter plates with a kinetic reader or on some clinical chemistry analyzers. The determined dynamic range goes up to 24 U/L. Results can be retrieved within about half an hour. The ...