Burgener Nebulizer Flyer

Compatible with a variety of glass and HF resistant cyclonic spray chambers for use with PerkinElmer®, TJA, Varian and Spectro ICP & ICP-MS spectrometers.CANADA • INTERNATIONALTel.: (800) 361-6820/+1 (514) 457-0701Fax: (800) 253-5549/+1 (514) 457-4499FRANCETel.: +33 (0) 1 69 18 71 17Fax: +33 (0)1 60 92 05 67GERMANYTel.: +49 (0) 8342-89560-61Fax.: +49 (0) 8342-89560-69CHINATel.: +86 (10) 87583441 Fax: +86 (10) 87583471PROVIDING INNOVATIVE SOLUTIONS TO ANALYTICAL CHEMISTSMINI X-FLOW Nebulizer For ICP & ICP-MSMANUFACTURED FROMACID RESISTANT ULTEM PLASTICIDEAL FORHIGH SOLIDSAPPLICATIONS:Up to 30% TDSwww.scpscience.comONLINEWebsite: www.scpscience.comEmail: sales@scpscience.comMini X-Flow NebulizerThe Mini X-Flow nebulizer is part of a new family of SCP SCIENCE ICP nebulizers, spray chambers and torches offering versatility unmatched in today’s analytical market. With the Mini X-Flow nebulizer, one can eliminate the need to change ICP sample introduction components for different applications or different sample types.Whether your samples are clean waters, suspensions, sludges or samples with high dissolved solids, the Mini X-Flow nebulizer can handle them all - and with the best performance. Manufactured from acid resistant Ultem plastic, and a platinum iridium sample inlet coupled to a sapphire crystal, the Mini X-Flow nebulizer may run samples in any acid matrix (including hydro-fluoric acid). The Mini X-Flow nebulizer is designed to be used with specific Teflon® insert-ready SCP SCIENCE cyclonic spray chambers. PerformanceA comparison of the Mini X-Flow nebulizer detection limits with those of other popular nebulizers. Included in the study were glass concentric and Teflon® parallel path nebulizers. Results show equal to, or better detection limits using the Mini X-Flow nebulizer (see graph 1).For high solid samples, the Mini X-Flow nebulizer provides excellent performance for solutions containing as high as 30% TDS (Total dissolved solids).Tests* prove the Mini X-Flow’s superior performance over a wide range of elements in varying solids concentrations (see graph 2).*For a copy, please contact SCP SCIENCE.Baffled glass spray chamber020-051-113Platinum Iridium Sample InletGraph 1 - Detection limit comparisonGraph 2 - Short term stabilityOperational SpecificationsSample Flow Rate: 0.8 - 3.0 ml / minArgon Gas Flow Rate: 1.0L / minOperating Pressure: 25-40 psiUnbaffled Ultem spray chamber020-051-111Figure 2Ultem spray chamber with Mini X-Flow nebulizerFigure 1Ultem spray chamber with Teflon® insertTeflon® InsertFigure 3 Ultem body180OBaffled Ultem spray chamber020-051-211180OBaffleUltem Spray ChamberThe Ultem spray chamber can also be supplied with a Teflon® insert for use with 6 mm diameter concentric or parallel path nebulizers (Figure 1). The Mini X-Flow fits directly on the spray chamber inlet port negating the need for the Teflon® adapter Figure 2). This inert spray chamber is unique because it’s made of 3 components (a top cap, middle body and bottom base) that can be assembled and dissembled easily. This design makes cleaning the spray chamber simple and trouble-free.CompatibilityWhith the SCP SCIENCE Ultem spray chamber, customers enjoy the ultimate in flexibility. By unscrewing the top and bottom, the body can be flipped to convert the spray chamber from left hand nebulizer entry to right hand entry allowing the spray chamber to be used in different manu-facturers’ instruments in the lab. The top can be converted from baffled to unbaffled by simply switching the top portion of the spray chamber. When the Mini X-Flow nebulizer is used with the SCP SCIENCE Ultem spray chamber (sold separately), the pair provides the best choice for HF resistant operation.AdvantagesCyclonic spray chambers provide superior wash out times compared to traditional Scott spray chambers. Choose a baffled spray chamber for samples containing high solids or unbaffled when the nebulizer is to be used with cleaner solutions.Ordering InformationThe Mini X-Flow nebulizer is supplied with both sample inlet tubing and gas inlet tubing. Gas connectors, also manufactured from acid resistant Ultem, are fitted at the instrument end for a click-in-place installation. To place an order or for additional product information, please contact your local sales representative or distributor.ITEM QUANTITY CATALOGUE NUMBERMini X-Flow nebulizer, Ultem 1 020-060-611Spray chamber, with baffle, Ultem, 4mm drain, with Teflon® insert 1 020-051-211Spray chamber, without baffle, Ultem, with Teflon® insert 1 020-051-111Clamp, stainless steel, #12 1 020-048-201Top with baffle for Ultem spray chamber 1 020-051-214Top without baffle for Ultem spray chamber 1 020-051-215DESCRIPTION MODEL OEM # CATALOGUE NUMBERSpray chamber, cyclonic, baffled 12mm -axial torch connection, 4mm drain PerkinElmer 2000/4000/5000/7000 DV, 3000 DV N0776053 020-051-113Spray chamber, cyclonic, Quartz baffled, 12/5-axial torch connection, 2mm drain PerkinElmer SCIEX ELAN 5000, 6000 Series, 9000 Series, DRC II --- 020-051-132Spray chamber, cyclonic, 11.3 mm-axial torch connection, 4mm drain PerkinElmer 2000/4000/5000/7000 DV, 3000 DV --- 020-051-141Spray chamber, cyclonic, baffled 12/5-radial torch connection, 4mm drain PerkinElmer Optima 4300V N0771501 020-051-126Spray chamber, cyclonic, water cooled, baffled 9.5mm-axial torch connection , 10mm drain Thermo (TJA) Iris, Tracescan, Trace, Advantage, Intrepid Spray Chamber --- 020-049-201Spray chamber, cyclonic, baffled 9.5mm x 80mm-radial torch connection, 4mm drain Thermo (TJA) 61E Polyscan, Atomscan 16 & 25, Advantage Radial, IRIS & POEMS --- 020-051-101Spray chamber, cyclonic, 9.5mm x 40mm-axial torch connection, 4mm drain Thermo (TJA) Trace Advantage Axial, Trace Scan, IRIS AP & POEMS --- 020-051-295Spray chamber, cyclonic, 9.5mm x 40mm x 100mm long-axial torch connection, 4mm drain Thermo (TJA) Trace Advantage Axial, Trace Scan, IRIS AP & POEMS 14451500 020-051-296Spray chamber, cyclonic, 12/5-radial torch connection, 4mm drain angled Thermo (TJA) Iris, Tracescan, Trace, Advantage, Intrepid Spray Chamber --- 020-051-429Spray chamber, cyclonic, baffled 12/5-radial short torch connection, 4mm drainVarian, 700-ES Series Radial, Vista Radial, Liberty 100/120/150/200/220 Spray Chambers --- 020-054-074Spray chamber, cyclonic, 8mm -radial torch connection, 4mm drain Varian, 700-ES Series Radial, Vista Radial, Liberty 100/120/150/200/220 Spray Chambers --- 020-054-162For Varian® UsersCatalog No.020-070-010For PerkinElmer® UsersCatalog No.020-070-005MK-MINI_X_FLOW_BROC-8.0-EGlass Spray ChambersEach spray chamber is fully compatible with the Mini X-Flow nebulizer.Ultem Nebulizer & Spray ChambersFor SPECTRO® UsersCatalog No.020-070-015NEW Long Lasting Alumina Injector TorchesNOTE: Contact your local sales representative for more information on these patent pending torches. Several models are available for other ICP systems.
Most popular related searches

Contact supplier

Drop file here or browse