True hemisphere design. Titanium plasma spray coating. Designed to maximize head size while maintaining bearing thickness. Combination taper and snap locking mechanism. Anti-rotational tabs are flush with the shell on all liners. +0 liner face truly flush with the ...
The Legend Shell is Ortho Development’s newest acetabular solution featuring a highly porous coating technology. Sintered titanium shards establish a scratch-fit feel during insertion and enable initial implant stability. The 3D porous structure with 60% porosity supports longterm ...
Porous Titanium coated modular shells designed for use with HLXPE modular liners. Compatible with CoCr and Biolox® modular femoral heads. The Libertas® Modular Shell has been designed to accept Highly CrossLinked Ultra-High Molecular Weight Polyethylene liners. The liners accommodate a range of Cobalt Chrome or Biolox® Delta Ceramic heads in varying size and neck-length /offset ...
U-Motion II PLUS utilizes a Titanium Plasma Spray PLUS (TPS PLUS) coating technology for increased roughness. Titanium Plasma Spray PLUS coating technology designed to provide outstanding bonding strength and ‘scratch fit’ for initial stability. ...
The CS2 Acetabular Cup System has evolved from the clinically proven Consensus® Hip System. The roughened titanium porous coating is manufactured from sintered irregular beads to enhance initial stability as well as long-term biological fixation. The optional flared rim design improves the press-fit in the highest quality bone. Instruments include both straight and offset reamers and shell ...
The Prime Acetabular Cup System is optimized for a polyethylene bearing surface, eliminating the compromises associated with alternative ...
The Full XPE Cup is designed for cemented fixation in primary or revision hip arthroplasty. Made from XPE (Highly Crosslinked Polyethylene) material, the cemented cup is designed to provide optimal stability and improved longevity. The Full XPE Cup can be combined with a larger size femoral head to improve range of motion and reduce the potential for ...
U-Motion II is a comprehensive acetabular hip system offers a wide range of acetabular cup, liner, and femoral head prostheses options for primary and revision hip ...
Pelvic plates are designed for reconstruction of Pelvic and acetabular bone with difficult geometry and enables the fixations with specially designed instruments. Accetabulum, Pelvic Ring, Saccrum, Illium, Sacro-illium joint, Synphisis Pubis. ...
The MBQ high torque rotary handpiece provides the surgeon with ample power even for the most demanding of acetabular reaming procedures. The new drill/ream handpiece produces over 30% more reaming torque and speed than the previous generations. The powerful dedicated sagittal saw cuts through the hardest of bone with ease and ...
Cannulated drilling and reaming is made possible by our patented adapter. Provides power for acetabular reaming and precision for small bone surgieres. Drill bits and reamers with AO Small, Zimmer and Hudson type quick-connect shanks can be easily connected. Round shanks, pins, wires and remaing quick-connects can be securely gripped using a range of 3-jaw chucks including the high-capacity 10mm ...
The United Dual Mobility (UDM) Acetabular System is applied in a primary or revision total hip arthroplasty for acetabulum reconstruction. Based on two classic concepts, Sir Charnley’s low friction principle and the anti-dislocation theory by using larger femoral head diameter, the cobalt-chrome alloy-based UDM Acetabular System provides greater range of motion and superior jumping distance ...
All the cemented Acetabular Cups can be implanted via any standard approach for total hip arthroplasty, depending on the surgeon's level of experience. ...
The Echo Femoral Hip System offers a modern metaphyseal loading fit and fill design to address increasing hospital demands for both primary and fracture applications. Four stem options with various fixation modes address the distinct needs of each patient, while the customizable instrumentation platform provides enhanced surgical workflow. Zimmer Biomet addresses the unpredictability of fracture ...
The H1 is a contoured ceramic-on-ceramic hip resurfacing arthroplasty system. It consists of two monoblock implant components (femoral head and acetabular cup) made of BIOLOX®delta with vacuum-plasma-sprayed titanium and hydroxyapatite for cementless fixation. The contours of the H1 components are designed to better reflect the native morphology of the femoral head and acetabulum. The H1 is ...
The only truly patient-specific total hip replacement implant The Conformis Hip System, introduced in July 2018, is the only primary total hip replacement system on the market designed with 3D imaging technology to provide a stem and acetabular cup size that matches each patient’s specific ...
The H1 is a contoured ceramic-on-ceramic hip resurfacing arthroplasty system. It consists of two monoblock implant components (femoral head and acetabular cup) made of BIOLOX®delta with vacuum-plasma-sprayed titanium and hydroxyapatite for cementless fixation. The contours of the H1 components are designed to better reflect the native morphology of the femoral head and acetabulum. The H1 is ...
The EZX System is exclusive to Brasseler Surgical Instrumentation. Its proprietary design allows easy access for the removal of cemented and non-cemented acetabular cups during hip revision surgery. The system utilizes powered technology with a single rotating blade to reduce surgical procedural time and the risk of acetabular fractures. The 29 blade options make a precise cut with predictable ...