AMB Ecosteryl - Model 250 - Medical Waste Disposal Equipment
AMB Ecosteryl Serial 250 is ideal for regulated medical waste (RMW) and hazardous waste disposal service providers. Its continuous process allows it to handle 250 to 300 kg/hr which is up to 4000 L of medical waste.
-
Most popular related searches
Product Details
- Capacity : up to 300 kg/hr (660 lbs/hr)
- Volume capacity per hour : approx. 4000 liters
- Length: 12m
- Width : 3.5m
- Height : 5.2m
- Weight : 12 tons
- Required floor space : 15 x 6m
- Minimum ceiling height : 6m
- Electric power consumption : 50-80 kWh
- Electric power consumption per ton : 240-320 kWh/t
- Electrical connection power : 3-phase / 240 Amp – starter motor
Product Description
- Transfer screw with microwave cavity
- Heat-insulated hopper with electric resistances
- Patented four-shaft shredder
- Microwave system, patented high technology
- Microwaves power: 24 kW
- Shredder power: 37 kW in four rotating shafts
- Microwaves frequency: 2.450 MHZ
- Fail-safe technology with alarms
- Challenge (Quality Control) Protocol using SCBIs and incubator
- Treatment parameters continuously monitored and maintained during the process
- No intermediate handling of medical waste during the process
- Weighing system
- Automatic loading system with lifter and dumper for wheelie bins
- Hydraulic ram (optional)
Customer reviews