AnyScan - Model TRIO SPECT/CT - Multimodality NM Imaging System
From Clinical Products - AnyScan TRIO Family
The only triple-detector SPECT/CT for high-end clinical and research applications with parallel hole and multi-pinhole collimation. AnyScan TRIO® SPECT/CT imaging system without any compromise to realize perfect SPECT resolution and excellent image quality. The unique triple head detector design enables detailed imaging by applying a reduced acquisition time. The system becomes a perfect nuclear medicine multimodality equipment with the supplement CT subsystem. With the addition of multipinhole collimation, the AnyScan TRIO® system breaks further boundaries in molecular imaging.
-
Most popular related searches
Features & Benefits
Nuclear Medicine clinical practice requires high-throughput imaging systems that allow a significant reduction in acquisition times without degrading image quality. This is a legitimate request and our answer is the AnyScan TRIO® SPECT/CT multimodality imaging system.
- Decrease Acquisition Time: The average acquisition time can be reduced to a quarter. A whole body bone SPECT/CT scan can be implemented in less than 20 minutes. The shorter acquisition time helps to improve patient comfort and decrease the chance of motion artefacts.
- Maximize Image Quality: Improve diagnostic accuracy and confidence. Significantly higher system resolution and two times better contrast to noise ratio become available compared to the conventional two detector head SPECT systems.
- Reduce Administered Activity: Minimize patient dose and reduce the exposure of the administrator. The smaller amount of applied tracers can dynamically reduce the average radiotracer cost.
Neurodegenerative diseases, like Alzheimer’s and Parkinson’s disease is of paramount importance in nuclear medicine thus Mediso introduces dedicated Brain SPECT multipinhole apertures and matching iterative reconstruction.
- The main application is the brain imaging where a PET-like image resolution could finally be realized
- High resolution brain imaging. One aperture for Alzheimer, Parkinson, Epilepsy
- Shorter acquisition time with usual patient dosage allows 10 minute patient examinations
- Improved heart acquisition methods with extreme high sensitivity and high resolution outcome
- Even 2 minutes long cardio acquisition is possible in a special stationary collection
- Lateral movement of the patient table helps to centralize the heart
The flexible AnyScan® SPECT system is supplemented by a 16-slice, low dose CT which results in a high resolution image. The detailed CT images help to localize anatomical aberrations and disorders accurately and give an exact input to SPECT acquisition planning. Attenuation correction from the CT image and our special Tera-Tomo™ 3D CT engine ensures sharp, detailed images. Metal correction function is available in CT reconstruction to reduce image artifacts caused by high attenuated orthopedic implants (e.g hip, knee, shoulder).
Scalable Detector performance for research & routine imaging
- 94(*3) / 123(*3) PMT, high resolution Xtreme Edition Detectors for multipinhole and parallel hole collimators for research and high energy theranostic imaging
- Up to 3.0 mm resolution
-
Theranostic imaging with 19.1mm crystal high resolution detector
- Theranostic imaging combined with therapy, is a rapidly growing application in cancer molecular imaging
- To comply with the emerging sophisticated therapy need from clinical side, Mediso offers special detector perfect for theranostic imaging
- Improved image quality for treatment purposes
- Support of therapeutic isotopes such as I-131, Y-90, Lu-177.
- Quantitative imaging
Applications
MPH Cardiac
67 years old female patient. Images acquired with AnyScan TRIO SPECT/CT with multipinhole collimator. This collimator could give coronarial blood flow information after the injection.
- Collimator: MPH-Cardiac (multipinhole)
- Radiotracer: Tc-99m MIBI
- Applied dose: 354 MBq
- Acquisition: 7 minutes
Specification
SPECT
PET-like resolution
Up to 3 mm system resolution achievable
MPH apertures
Brain, Cardiac, other organ specific
Fast workflow
Max. 20-min WB SPECT with CT
Head positions
120°, 180° or special Heart position
Count rate
Up to 700 kcps
CT
Number of physical slices
16
Diagnostic CT
Yes
Resolution
Submillimeter: 0.625 mm
Rotation speed
0.5 - 2 sec
Bore size
70 cm
Tube current
10 - 440 mA
Anode heat capacity
7.5 MHU
MPH APERTURES
Available
Brain, Cardiac, other organ specific
Cardiac MPH
360° rotational or stationary
Brain MPH
for typical diseases e.g.: Alzheimer, Parkinson, Epilepsy, etc.
SOFTWARE
General acquisition, device control
Nucline™ with all protocol sets
General processing
InterView™ XP
Evaluation software
InterView™ FUSION
Advanced cardiology
INVIA's 4DM for SPECT, Emory Cardiac Toolbox, or Cedars Sinai modules
Advanced neurology
Syntermed - NeuroQ package (Emory), Segami - Neurogam, Shina - 3Di
Customer reviews
No reviews were found for AnyScan - Model TRIO SPECT/CT - Multimodality NM Imaging System. Be the first to review!