Capenergy - Model C300 - Phlebology & Aesthetic Medicine. Manual or Automatic Tecartherapy Medical Device
Phlebology & Aesthetic Medicine. Manual or Automatic Tecartherapy Electrical Transference of Capacitive and Resistive Energy (3 channels) This model has 3 working channels, allowing operation in female problem areas: cartridge and abdomen at a time. Model widely used in aesthetic medicine clinics.
-
Most popular related searches
Details
Phlebology & Aesthetic Medicine. Manual or Automatic Tecartherapy
Electrical Transference of Capacitive and Resistive Energy (3 channels)
This model has 3 working channels, allowing operation in female problem areas: cartridge and abdomen at a time. Model widely used in aesthetic medicine clinics
Capenergy models are designed to provide enough energy output to generate an optimal biological effect, while maintaining the safety conditions.
All devices are equipped with an overload alarm, which protects the equipment andthe patient before any excessive of energy. Capenergy machines have a safety circuitthat allows patients to monitor therapy.
Technical Characteristics
- Frequency: 0.8MHz, 1 MHz, 1.2MHz
- CAPACITIVE:
Automatic Capacitive Plates Outlets: 3 (2 if you use the manual output of channel 3)
Manual Capacitive Outlets: 3 (2 if you use the manual output of channel 3)
Passive Plates Outlets: 3
Manual Resistive Outlets: 1 (none if you use the automatic outputs of channels 1,2&3)
- Voltage and output power:
- Automatic & Manual Modules 40 / 1000
- V rms (aprox.) 320 – 380
- Watt rms (aprox.) 130 – 75
- Voltage: 230Va.c. +/- 10%
- Maximum input power: 930 W
- Weight: 20,3 Kg. With stand 40,1 Kg
- Dimensions: 556 x 420 x 220 mm
- Ambient operating temperature: 0 – 40° C
- Maximum temperature for storage and transport: 0 + 70° C
- Maximum storage and transport humidity: 25 + 85%
- Automatic plate surface: aprox. 240 cm2
- Capacitive electrodes: Ø 33 mm – Ø 53 mm – Ø 65 mm
- Resistive electrodes: Ø 33 mm – Ø 53 mm – Ø 65 mm
- Classification for electrical safety: Class 1
- Frequency Selection: Yes. In need of therapy: 0.8 MHz. 1 MHz. 1.2MHz.
- Tuning Frequency in Different Therapeutic Areas from the same patient: Yes. The operator can select the frequency of interest in each of the channels (1 MHz 0.8 MHz 1.2 MHz).
- Number of Channels Available: 3 (Equivalent to treat three areas of the patient´s body simultaneously)
- Intelligent Channel: Yes. The same channel allows you to use the manual capacitive and resistive handprobe, and the capacitive automatic plate.
- Multichannel Technology: Yes.
Application of the capacitive electrode in the three channels: Yes.
Application of the resistive electrode in the three channels: Yes.
Application of the automatic plate in the three channels: Yes.
- Automatic Technology: Sí.
- Option of Crossfires (manual CAP-RES combined application): Yes.
- Option of Combined Manual & Automatic Treatments: Yes.
- Option of Bilateral Lymphatic Drainage –unattended–: Yes.
- Temperature Monitoring by Sensor: Yes. In automated plates only.
- Suggestions of Treatment by Guided Program: Yes. (Athermal. Thermal. Highly thermal).
- Basic or Advanced Screen: Yes
- Viewing Biofeedback Parameters (absorbed energy , qualitative indication of real-time power, coupling, temperature), to conduct clinical research: Yes.
- Safety Switch: Yes.
- Hygiene Systems for Accessories: Yes. Protective membranes for manual capacitive handpieces, and pouches (with or without gel) for automatic capacitive accessories.
Customer reviews
No reviews were found for Capenergy - Model C300 - Phlebology & Aesthetic Medicine. Manual or Automatic Tecartherapy Medical Device. Be the first to review!