Jarvik 2000 - Model VADs - Ventricular Assist Devices (VADs)
The first ventricular assist devices (VADs) developed decades ago were meant to sideline the failing biological heart of a heart failure patient. These pumps were heavy, bulky devices that drew blood from the left ventricle through an intake valve and moved it into the aorta at as much as 10 liters per minute — the full output of a healthy heart.
-
Most popular related searches
Details
Held in the hand, the tiny, valveless Jarvik 2000 Ventricular Assist Device is about the size of a C battery. Within its welded titanium shell sits a direct-current motor, a rotor supported by two ceramic bearings, a single moving part: a small, spinning titanium impeller that pumps blood from the heart at up to 8.5 liters per minute. Rather than take over for the biological heart, the Jarvik 2000 augments the weakened heart’s blood output to help restore normal blood flow throughout the body.
By utilizing the heart’s remaining strength, the Jarvik 2000 takes a simple, unobtrusive approach to circulatory support. Any muscle that gets too little exercise becomes “out of shape,” and the heart is no exception. The Jarvik 2000 allows the patient’s heart to continue to exercise as it recovers after surgery.
The pump is designed to minimize patient reliance on mechanical support, avoid risk and redundancy in its function, and give the patient the best chances of recovery.
Simplicity
The fundamental principle at work in the design of the Jarvik 2000 FlowMaker® is simplicity.
Simplicity begets many strengths, including ease of use and reliability. While some ventricular assist devices have inflow and outflow valves, which require a complicated integration of the device into the body, the Jarvik 2000 is valveless. The pump itself consists of a bullet-shaped shell of welded titanium surrounding two ceramic bearings and a rotor, which turns a single, small impeller at an adjustable speed. The whole pump sits inside the intact natural heart, so there is no need for extra inflow apparatus. Its mission is singular: to move blood from the left ventricle through the outflow graft to the aorta. Hence the name, “FlowMaker.”
Since heart failure patients retain some function of the left ventricle, the Jarvik 2000 acts simply to increase the weakened ventricle’s output. In doing so, it allows the heart to circulate blood more efficiently, thus alleviating many of the symptoms and potential problems associated with heart failure, including failure of the kidneys, liver and lungs, which commonly occur in the final days or weeks of life.
Portability
The Jarvik 2000® Ventricular Assist Device can be powered for 8-10 hours on a single rechargeable Lithium-ion battery pack that weighs less than two pounds. The pump draws power from the battery, worn externally, via a wire that exits the skin either through the abdominal wall or a connector mounted behind the ear.
With so much life per portable battery, the Jarvik 2000 permits patients to roam tether-free longer than other VADs that consume more power. The durability of the external battery and controller mean that patients can take the device almost anywhere. The external equipment required by the Jarvik 2000 is also minimal: the total weight of the battery and controller is less than three pounds and can be carried comfortably in a shoulder bag or waist-belt. Batteries can be recharged at any wall outlet, and some patients carry several extra batteries, especially when traveling.
Manual Control
The Jarvik 2000® Ventricular Assist Device is monitored and its output adjusted by each patient according to his or her circumstances and needs. We believe that manual control remains the most sensible approach to regulating the operation of VADs. While faulty calculations or bad sensor data can wreak havoc on a microprocessor-controlled system, an educated patient provides highly responsive, adaptable and safe control system unmatched by computers. Manual control also gives patients and doctors more leeway to respond to changing circumstances.
The Jarvik 2000’s external controller is designed with ease of use in mind and has a user-friendly control interface. Using a dial numbered from 1 to 5, the patient manually adjusts the rate at which the Jarvik 2000 pumps blood to suit his or her level of activity – turning it up when exercising and down to go to sleep. The range of speeds offered by the controller is broad enough to give the patient flexibility in choosing and accommodating different activities, but narrow enough to prevent unsafe extremes. Patients and their caretakers are provided with guidelines for making adjustments to pump speed, and they quickly become comfortable doing so.