Human Diagnostic Equipment & Supplies
34 equipment items found
by:Hemagen Diagnostics, Inc. based inColumbia, MARYLAND (USA)
For the detection and titration of C. trachomatis IgG antibodies in human sera903000 - 96 Determinations Kit, 12 x 8 Well Slides - Methodology IFA. 903001 - 12 x 8 Well Slides Only - Methodology IFA. 903004-S - 2 mL Conjugate, FITC labeled goat anti-human IgG with counterstain - Methodology ...
by:Hemagen Diagnostics, Inc. based inColumbia, MARYLAND (USA)
For the qualitative and semi-quantitative determination of circulating rheumatoid factor in human serum6413 - 192 Determinations Kit - Methodology ...
Manufactured by:Operon S.A. based inCuarte de Huerva (Zaragoza), SPAIN
A positive signal in the test indicates the presence ofC.difficilein the stool sample. Subsequent analysis of the sample with a test for detectingC.difficiletoxins (such as our 2A-Bdiff test) confirms whether the strain is toxigenic and, therefore, pathogenic and disease-causing. Some of the leading healthcare societies propose the use of a two-step protocol for identifying ...
by:Hemagen Diagnostics, Inc. based inColumbia, MARYLAND (USA)
For the detection of circulating antibodies to Trypanosoma cruzi, the causative agent of Chagas' disease66101 - 96 Determinations Kit - Methodology ...
by:Hemagen Diagnostics, Inc. based inColumbia, MARYLAND (USA)
For the detection and semi-quantitation of anti-neutrophil cytoplasmic anbodies (ANCA) in human serum904200 - 60 Determinations Kit, 10 x 6 Well Slides (Human granulocyte, ethanol fixed) - Methodology IFA. ...
by:Hemagen Diagnostics, Inc. based inColumbia, MARYLAND (USA)
An enzyme-linked immunosorbent assay (ELISA) designed for the quantitative measurement of circulating IgA autoantibodies to cardiolipin66015 - 480 Determinations Kit (5 x 96 Well) - Methodology EIA. 66025 - 96 Determinations Kit, Lyophilied Reagents - Methodology ...
Manufactured by:Operon S.A. based inCuarte de Huerva (Zaragoza), SPAIN
One-step immunochromatographic test for the simultaneous detection of Rotavirus and Adenovirus in feces. Rotaviruses are one of the main causes of acute gastroenteritis, particularly in children under two years of age. Transmission occurs through the fecal-oral route; the incubation period is between 1 and 3 days. Adenoviruses are the second leading cause of viral gastroenteritis in children ...
Manufactured by:Bioneer Corporation based inDaedeok-gu, SOUTH KOREA
AccuPower SARS-CoV-2 Variant ID2 Real-Time RT-PCR Kit(Mastermix type) is an in vitro diagnostic kit that helps diagnose SARS-CoV-2 variants. The spike gene (S gene) is the key region to monitor the mutants with the recent arising from emergence variants from SARS-CoV-2. The kit is able to detect 5 genes about S gene mutation hot-spots in 2 tubes. Sputum, nasopharyngeal swab, and oropharyngeal ...
Manufactured by:Operon S.A. based inCuarte de Huerva (Zaragoza), SPAIN
One-step immunochromatographic test for the differential detection of Norovirus Genogroups I and II in human faeces. Noroviruses are a type of single-stranded, positive-sense RNA viruses belonging to the family Caliciviridae. They are highly contagious viruses whose main routes of transmission are: person-to-person contact and through contaminated food/water (in the U.S. is estimated that they ...
Manufactured by:Operon S.A. based inCuarte de Huerva (Zaragoza), SPAIN
One-step immunochromatographic test for the qualitative detection of the Influenza virus types A and B (both types in separate bands) from respiratory samples such us nasopharyngeal swabs, washes and aspirates. ...
by:Hemagen Diagnostics, Inc. based inColumbia, MARYLAND (USA)
For the detection and titration of to antimitochondrial IgG antibodies in human sera902080 - 48 Determinations Kit, 12 x 4 Well Slides - Methodology IFA. 902090 - 12 x 4 Well Slides Only - Methodology IFA. 904260 - 48 Determinations Kit, 12 x 4 Well Slides (Mouse Kidney, Mitochondrial Antibody) - Methodology IFA. 904270 - 96 Determinations Kits, 12 x 8 Well Slides (Mouse Kidney, Mitochondrial ...
Manufactured by:Operon S.A. based inCuarte de Huerva (Zaragoza), SPAIN
One-step immunochromatographic test for the qualitative detection of Respiratory Syncytial Virus (RSV) from samples such as nasal swabs, nasopharyngeal washes or aspirates. Respiratory Syncytial Virus (RSV) is the leading cause of emergency rooms visits and hospitalisations for acute lower respiratory tract infections in infants and young children worldwide. RSV can also become a serious problem ...
Manufactured by:Operon S.A. based inCuarte de Huerva (Zaragoza), SPAIN
One-step immunochromatographic test for the differential detection of Rotavirus, Adenovirusand Norovirusgenogroups I and II in human faeces. Rotavirus is one of the main causes of acute gastroenteritis, particularly in children under two years of age. Transmission occurs through the fecal-oral route; the incubation period is between 1 and 3 days. Adenovirus is the second leading cause of viral ...
Manufactured by:Jackson ImmunoResearch Laboratories, Inc. based inWest Grove, PENNSYLVANIA (USA)
AffiniPure Alpaca Anti-Human IgG (H+L) ML* (min X Bov, Ms, Rb Sr ...
Manufactured by:SensitivE Audit based inStaten Island, NEW YORK (USA)
SensitivE Audit health level assessment devices are the premium segment in the range of SensitivE diagnostic tools. The device uses the advanced LifeStream program and is able to run complete diagnostics of a human body in a short space of time, without any harm to health. The main interface unit working on the method of frequency-wave imprinting ...
Manufactured by:BioGX, Inc. based inBirmingham, ALABAMA (USA)
Examples of open system platforms are the BD MAX™ System, Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms. Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed ...
Manufactured by:DIALAB® GmbH based inWr. Neudorf,, AUSTRIA
Form: Liquid, ready to use, Method: Impedancemetry, Sample: Whole blood, No. of cycles: ...
Manufactured by:BioGX, Inc. based inBirmingham, ALABAMA (USA)
Examples of open system platforms are the BD MAX™ System, Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms. Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed ...
Manufactured by:BioGX, Inc. based inBirmingham, ALABAMA (USA)
Examples of open system platforms are the BD MAX™ System, Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms. Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed ...
Manufactured by:InVivo BioTech Services GmbH a BRUKER Company based inHennigsdorf, GERMANY
InVivo is your partner for custom monoclonal antibody production from hybridoma cell lines. More than 3,500 different hybridoma clones producing human, rat, or mouse antibodies have been processed in our lab during the last 20 years. Your challenging clone is in good hands with us supported by special equipment and many years of know-how. Our facilities allow the production of up ...