Manufactured by:Genabio Diagnostics Inc. based inBedford, MASSACHUSETTS (USA)
cIntended Use: Fosun COVID-19 RT-PCR Detection Kit is a real-time RT-PCR test intended for the qualitative detection of nucleic acid from the SARS-CoV-2 in upper and lower respiratory specimens (such as anterior nasal swabs, mid-turbinate nasal swabs, nasopharyngeal swabs, oropharyngeal swabs, sputum, lower respiratory tract ...
Manufactured by:Advanced Molecular Diagnostics based inNottingham, UNITED KINGDOM
More than 1,000 mutations in the CFTR gene have been associated with cystic fibrosis. Most of these mutations in the CFTR gene change the production, structure, or stability of the chloride channel. All of these charevent the channel from functioning properly, which impairs the transport of chloride ions and the movement of water into and out of cells, resulting in cells lining the passageways of ...
by:TECOmedical AG based inSissach, SWITZERLAND
Using a patented 10-minute extraction step, the DermaGenius 2.0 multiplex RT- PCR detects more than 95% of the clinically important Dermatophytes in nail, skin and hair samples within 3 ...
Manufactured by:Boditech Med Inc. based inGangwon-do, SOUTH KOREA
PCR detection for Mycobacterium tuberculosis infection. This test comes in ready-to-use mixture. The user can use the reagent by dissolving the dry beads in a diluent followed by adding the pre-extracted DNA, and you can run PCR to assess the MTB ...
Manufactured by:MyBioSource, Inc. based inSan Diego, CALIFORNIA (USA)
bta-mir-139 Real-Time RT-PCR Detection and U6 Calibration Kit. Host/Reactivities: Reactivity: Bovine. Samples: miRNA, Total RNA. Assay Type: 2-Step qRT-PCR. Detection Range: Seven orders of magnitude. Sensitivity: 10 copies of a standard mimics and as little as 25 pg of total RNA. Applications: Real-time ...
Manufactured by:MyBioSource, Inc. based inSan Diego, CALIFORNIA (USA)
bta-mir-15a Real-Time RT-PCR Detection and U6 Calibration Kit. Host/Reactivities: Reactivity: Bovine. Samples: miRNA, Total RNA. Assay Type: 2-Step qRT-PCR. Detection Range: Seven orders of magnitude. Sensitivity: 10 copies of a standard mimics and as little as 25 pg of total RNA. Applications: Real-time ...
by:Xiamen Spacegen Co., Ltd. based inxiamen, CHINA
Detection Gene:Methodology for Detecting 8 Methylation Sites in the PAX1 Gene Promoter Using Multiplex Fluorescence PCR. Detection Significance:Auxiliary diagnosis of cervical ...
Manufactured by:Agilent Technologies, Inc. based inSanta Clara, CALIFORNIA (USA)
Total Confidence qPCR delivering flexibility, precision, and performance. The AriaMx Real-Time PCR System is a fully integrated quantitative PCR amplification, detection, and data analysis system. The system design combines a state-of-the-art thermal cycler, an advanced optical system with an LED excitation source, and complete data analysis ...
Manufactured by:Genabio Diagnostics Inc. based inBedford, MASSACHUSETTS (USA)
Intended use: Genabio Leukorrhea Panel is a multiplex PCR for simultaneous detection of Chlamydia trachomatis (C.trachomatis), Neisseria gonorrhoeae (N.gonorrhoeae) and Trichomonas vaginalis (T.vaginalis) in genital specimens from ...
by:TECOmedical AG based inSissach, SWITZERLAND
High sensitive PCR assays for the detection of viral, bacterial, fungal and parasital infections using monoplex and mutiplex test ...
Manufactured by:Liferiver Bio-Tech (United States) Corp. based inLa Jolla, CALIFORNIA (USA)
LightCycler 1.0 (Internal control can't be used for this system); LightCycler 2.0; PE5700, MJ-Opticon & other single color systems; ABI7000, ABI7300, ABI7500, ABI7900, ABI StepOne, StepOne plus, MJ-Opticon2, MJ-chromo4, MX3000P, MX3005P, Smart Cycler II, Rotor-Gene 6000, LightCycler 480, CFX 96, Slan 96, MIC, iCycler iQ4, iCycler iQ5 & other multi-color ...
Manufactured by:Genabio Diagnostics Inc. based inBedford, MASSACHUSETTS (USA)
Intended use: Genabio® Genital Ulcer Panel is a multiplex PCR assay for simultaneous detection of below mentioned three pathogens in clinical specimens. The three major causes of Genital Ulcer Disease (GUD) in the United States are Herpes simplex virus, Treponema pallidum (syphilis) and Haemophilus ducreyi (chancroid). ...
Manufactured by:BioGX, Inc. based inBirmingham, ALABAMA (USA)
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms. ...
Manufactured by:BioGX, Inc. based inBirmingham, ALABAMA (USA)
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems 7500 Fast Dx, QuantStudio™ 5, Bio-Rad CFX96 Touch™ and Bio-Rad CFX384 Touch™real-time ...
Manufactured by:BioGX, Inc. based inBirmingham, ALABAMA (USA)
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms. ...
Manufactured by:HymonBio Co.,Ltd based inSuzhou, CHINA
Hymon provides a flexible, quantitative PCR respiratory detection solution for quick and sensitive clinical testing, and provide accurate detection results for some of the most common respiratory diseases. Hymon® MULTONETM Respiratory Panel Test Kit adopts multiple qPCR technology and provides a combination panel for simultaneously ...
Manufactured by:BioGX, Inc. based inBirmingham, ALABAMA (USA)
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms. ...
Manufactured by:BioGX, Inc. based inBirmingham, ALABAMA (USA)
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms. ...
Manufactured by:altona Diagnostics GmbH based inHamburg, GERMANY
The FlexStar (RT-)PCR Amplification Mix 1.5 is a universal reagent to be combined with the Detection Mixes. The enzyme mix for real-time PCR has been especially developed for use with the different FlexStar® Detection Mixes targeting different ...
Manufactured by:JBS Science Inc based inDoylestown, PENNSYLVANIA (USA)
The GSTP1 Short Amplicon Methylation specific qPCR kit is intended to quantify the methylation GSTP1 gene promoter. The kit utilizes a two-step approach for quantification of PCR products on Roche’s LightCycler® 480 platform. Reagents in the kit include first and second step primers, methylation-specific probe, and controls sufficient for 50 reactions. The kit does not contain ...