Total Knee Arthroplasty Equipment
-
Manufactured by Pixee Medicalbased in FRANCE
A simple solution: Knee+ is used during total knee arthroplasty operations, it offers the orthopaedic surgeons an intraoperative assistance for the implant positioning with the help of augmented reality glasses. The cutting planes are oriented with respect to the patient mechanical axes calculated according to anatomical ...
-
based in USA
Providing tibial and femoral navigation for total knee arthroplasty in a palm-sized, single-use device compatible with all standard implant ...
-
Manufactured by OrthoSensor, Inc. - Strykerbased in USA
during primary and revision total knee arthroplasty (TKA). This disposable, intelligent device delivers data wirelessly to an intra-operative monitor that enables surgeons to make informed decisions regarding implant position and soft-tissue releases to improve knee balance and stability through the range of motion. This monitor ...
-
Manufactured by Exactech, Incbased in USA
Revision total knee arthroplasty cases are expected to triple by 2020, due to the growing size of the aging population and increasing number of primary total knee arthroplasty cases.1 The Truliant® Revision Knee System helps you address the reconstructive challenge with a ...
-
Manufactured by MedSpark, LLCbased in USA
During Total Knee Arthroplasty (replacement) or TKA, a patellar component (commonly composed of UHMW polyethylene) is typically located by the surgeon on the posterior aspect of the patient's existing patella. The patellar surface must be prepared by the surgeon to accept the patellar component and a patella clamp instrument is typically ...
-
Manufactured by Intellijoint Surgical Inc.based in CANADA
Intellijoint KNEE is a fast and easy-to-use surgeon-controlled navigation system that provides real-time measurements of your surgical cutting guides during total knee arthroplasty (TKA). Quantitative measurements of varus/valgus, femoral flexion and tibial slope angles, and resection depth help you accurately ...
-
Manufactured by Euromed Implants GmbHbased in GERMANY
Quadrofit Total Knee System is designed and developed for use in cemented and cementless application of Total Knee arthroplasty. The unique femoral cutting guide combines various functionalities in one component. This enables the surgeon to shape the femur fast and accurate with only one guide positioning and ...
-
Manufactured by Kinamed Incorporatedbased in USA
The NaviPro® Knee navigation system provides computer-aided navigation of surgical instruments. Specifically, its purpose is to aid in the accurate resection of the distal femur and proximal tibia in total knee arthroplasty. It also allows the surgeon to intra-operatively measure flexion range of motion and ligament balance. ...
-
Manufactured by MicroPort Scientific Corporationbased in CHINA
Skywalker™ is a robotics system independently developed by MicroPort to carry out total knee arthroplasty (TKA), completed First In Man Clinical Trial (FIM) at Ninth People’s Hospital Shanghai on June 30th 2020. Director Li Huiwu and his team successfully completed the operation on a female patient to restore her lower limb ...
-
Manufactured by MedSpark, LLCbased in USA
Total Knee Arthroplasty (replacement) or TKA is a surgical procedure in which the knee joint is replaced by a prosthetic implant. During this procedure, the distal end of the femur must be prepared to accept the femoral component of the replacement joint construct. Following the initial resection, a saw guide is temporarily ...
-
Manufactured by MedSpark, LLCbased in USA
Total Knee Arthroplasty (replacement) or TKA is a surgical procedure in which the knee joint is replaced by a prosthetic implant. During this procedure, the distal end of the femur must be prepared to accept the femoral component of the implant. During a typical surgical procedure, a sagittal saw (see pictures) is utilized by the ...
-
Manufactured by Merete Technologies, Inc. (MTI)based in USA
The OsteoBridge™ IKA, Intramedullary Knee Arthrodesis, system serves to fuse the knee joint. The use of the implant is also possible to bridge long bone defects and to resect the metaphyseal area of the femur and tibia. OsteoBridge™ IKA (Intramedullary Knee Arthrodesis) knee arthrodesis allows cementless or cemented ...
-
Manufactured by Smith & Nephew plcbased in UNITED KINGDOM
RI.KNEE NAVIGATION puts the surgeon in control of assessing the individual patient disease state and predicting the knee stability over the full range of motion. Navigating gets even better* with a simplified, touch-free interface, pinless options and easy-to-use CLEARLENS ...
-
Manufactured by Marsi Bionics, S.L.based in SPAIN
First robotic knee orthosis with adaptable stiffness, which interprets the needs of the patient and provides the strength, mobility and stability necessary to be able to walk. Sensors provides biomechanical analysis of the patient’s gait and works to improve ...
-
Manufactured by Kinamed Incorporatedbased in USA
Designed specifically for the small but challenging group of patients with isolated, end-stage patello-femoral disease, the KineMatch PFR (Patello-Femoral Replacement) offers a uniquely effective and conservative resurfacing solution. Because the device is precisely pre-fitted to the patient’s anatomy using CT (Computed Tomography) data, no resection of femoral bone is required. This also ...
-
Manufactured by Mizuho OSIbased in USA
The gold standard for patient positioning in fracture and hip procedures, the Hana is revolutionizing orthopedic ...
-
Manufactured by Ankasa Regenerative Therapeuticsbased in USA
outcomes after spinal fusion surgeries. Our product has expansion opportunities to other bone reconstructive procedures including osseointegration of dental and orthopedic implants (knee and hip replacements), fracture repair, total joint arthroplasty revisions, and ...
Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you