Mediaid - Model 960 - Pulse Oximeter
From Vital Sign Monitors
Model 960 Pulse Oximeter with NIBP, Temperature & Printer Option. Applications: Emergency Care, ICU Care, Surgery Room, Hospitals, Physician's office, Specialty Clinics, Diagnostic Centers.
Features
- Compact Pulse Oximetry System for monitoring Oxygen Saturation (SpO2), Pulse Rate (BPM), Non-Invasive Blood Pressure (NIBP) and Temperature
- Bright, High resolution LCD screen to display the pleth wave form as well as the SPO2 and Pulse Rate readiungs
- Seperate bright LED displays for systolic, diastolic and mean Blood Pressure readings.
- Printer facility for printing reports immediately
- Accurate BP readings in less than 40 seconds
- Nurse call facility that alerts the nurse station in case of emergency
- 24 hour Patient Data storage and trend data
- Patient data transfer to a computer
- Software for patient data analysis (Optional)
- Rechargable battery with internal charger
- Monitors Adult, Pediatric Parents Weighing above 5 kg
Monitor Functional Specifications
Monitor Functional Specifications
- Display: High resolution fluroscent backlight 240 X 64 LCD graphical screen for Pleth waveform, Spo2 and BPM readings; 3-digit, bright 7-segment LED displays for NIBP readings
- Language Options: English
- Indicator: 7-waveform display; Alarm indicating light; External DC supply indicating light; QRS voice & voice alarming
- Interface: Measurement parameter cable interface; Power supply socket; Simulated signal output (1V & 5V amplitude optional, tolerance Battery: Chargeable up to 1 hour backup
- TREND Time: 1–72 hours
- Recorder: Optional
Non- Inversive Blood Pressure
- Technique: Oscillometric
- Measurement Range: Systolic 40-260mmHg; Diastolic 20-200mmHg; Pulse 40-200BPM
- Accuracy: 3mmHg
Physical Dimensions
- Dimensions: 202W x 262H x 110D (mm)
- Weight: 3.4 kg
Enviornmental Conditions
- Atmospheric Pressure: 760mmHg
- Humidity: 5 to 95%( non condensing)
- Operating Temp: 0 - 40C
- Storage / Transport Temp: Dual-channel
- No. of Channels: 1 channel, dispalying 1 TEMP value
Electrical Ratings
- AC Voltage: 100–230V AC, 50 / 60 Hz
- Battery Type: Rechargable Internal Battery 12V
- Battery Minimum Run Time: 2 hours in power save mode, no printing and NIBP running at 90min interval; using new fully charged battery
SpO2
- Measurement & Alarm Range: 0–100%; Resolution: 1%; Precision: ±2% (70–100%), ±3% (60–70%), Not specified (below 60%)
- PR & Alarm Range: 0–254 bpm; Resolution: 1bpm; Precision: ±1%
Customer reviews