MEDICOR BabyLife - Model BLF-2001T - Transport Incubator
Main body includes the hood, controller, bassinet, internal battery and observation lamp, skin temperature sensor, IV pole, mattress, adjustable stand
Specifications
- Air mode (temperature range: 25–37ºC, in override mode 37–38ºC) and Skin mode (temperature range: 34–37ºC, in override mode 37–37.5ºC) controlled by micro-computer;
- Power supply AC230V/50Hz and DC12V/10A or DC24V/6A alternatively.
- Input power: 400VA;
- Set temperature, air temperature, skin temperature and internal battery voltage can be displayed separately;
- Failure alarm indication: over-temperature, temperature deviation, sensor, motor fan failure, power failure;
- Double wall acrylic glass hood with side door, the bassinet can be pulled out;
- Natural air flow humidity;
- The height of complete unit can be adjusted;
- Oxygen cylinder and oxygen supply configuration;
- Observation lamp
- HEPA Air filter
Options
- > 37ºC override temperature control mode
- Reusable / Disposable skin temperature sensor
- Oxygen cylinders with supply system
- Additional battery for longer operation
- Ambulance trolley
- PIP and PEEP controlled resuscitator
- O2/air blender
- Neonatal ventilator (only with ambulance trolly)
- Suction unit (only with ambulance trolly)
- Syringe pump (only with ambulance trolly)
- Ambulance aircraft base (custom design)
Featured Benefits
- Air temperature servo control w/ override (25-37 oC)
- Skin temperature servo control w/ override (34-37 oC)
- Humidity pad (450 ml)
- Glass-like transparent double wall hood
- Hood with front & side access door
- Hood with 2 noiseless, easy-to-open hand ports / windows
- Hood with 1 iris ports / windows
- Hood with 6 tube ports
- Drawable cradle with foam mattress
- Fixing straps
- Heavy duty stand with 4 castors (2 lockable, 3 height level, 95 - 132 cm)
- Gas cylinder holder (2 pcs)
- IV pole
- HEPA air filter
- Water resistant, foil-covered keypad with lock
- LED display for heating level/power/mode/lock/alarm
- 3 digit LED display for air/skin/battery and set
- Display of heating intensity
- Microprocessor controller
- Mains /Ambulance power cord
- Battery for 90 min operation time
- Visual and audible alarms and backup sensors
- Continuous self-test function during operation
- 110-120/220-230V/50-60Hz, 12V, 24V
Technical Data
- PHYSICAL ATTRIBUTES (STANDARD VERSION)
- Incubator body
- Height / Packing : 56/75 cm (22/30 in)
- Width / Packing : 96/109 cm (38/43 in)
- Depth / Packing : 56/65 cm (22/26 in)
- Weight / Packing : 65/80 kg (143/176 lbs)
- Standard trolley
- Height / Packing : 95-132/39 cm (37-52/15 in)
- Width / Packing : 133/138 cm (52/54 in)
- Depth / Packing : 54/61 cm (21/24 in)
- Weight / Packing : 37/45 kg (82/99 lbs)
- Ambulance trolley
- Height / Packing : 95-140/41 cm (37-55/16 in)
- Width / Packing : 192/210 cm (76/83 in)
- Depth / Packing : 54/28 cm (21/11 in)
- Weight / Packing : 43/67 kg (95/148 lbs)
- Mains voltage : 220/230V ±10% (default), 110/120V ±10% (upon request), 12V/10 Ah, 24V/6 Ah (Ambulance)
- Nominal frequency : 50/60Hz
- Nominal power consumption : 400VA
- Number of batteries : 1 pce (2 pcs as option)
- Working time of battery : 90 min
- Number of battery charge cycles : max. 200
- Charging voltage of battery : 12V/26AH
- Dimension of battery : 17x16x13 cm (7x6x5 in)
- Weight of battery : 9 kg
- Operating ambient temperature range : +10°C–+30°C (50°F–86°F)
- Storage/transport ambient temperature range : -40°C–70°C (-40°F–158°F)
- Operating (Storage) ambient RH range : 30%–75% (0%–93%)
- Operating (Storage) air pressure range : 800 hPa–1060 hPa (500 hPa–1060 hPa)
- HOOD / IV POLE SPECIFICATIONS
- Access door opening height : 23 cm (9 in)
- Mattress tray size : 35 x 63 cm (14 x 25 in)
- Mattress to hood height : 26 cm (10 in)
- Mattress size : 30 x 60 cm (12 x 24 in)
- Load of cradle : max. 10 kg
- Load of IV pole : max. 2 kg
- TEMPERATURE CONTROL MODES
- Temperature control modes : Air (standard) / Skin (option)
- Temperature display range : (Air/Skin mode) 5.0°C (41.0°F) to 65.0°C (149.0°F)
- Air mode control temperature range : 25.0°C (77.0°F) to 37.0°C (98.6°F), in 0.1°C increments
- Air mode control override temperature range : 37.0°C (98.6°F) to 38.0°C (100.4°F), in 0.1°C increments
- Skin mode control temperature range : 34.0°C (93.2°F) to 37.0°C (98.6°F), in 0.1°C increments
- Skin mode control override temperature range : 37.0°C (96.8°F) to 37.5°C (99.5°F), in 0.1°C incr
- PERFORMANCE
- Air flow velocity across mattress : under 30 cm/sec
- Temperature rise time : 22°C (72°F) ambient < 30 min
- Temperature variability : under 1°C (1.8°F)
- Temperature uniformity on the surface of the mattress : under 1.5°C (2.7°F)
- Correlation of the indicated air temperature with the actual incubator temperature : ≤ 1.5°C (2.7°F)
- Operating noise level in hood : under 50 dBA
- Carbon Dioxide (CO2) level (per EN60601-2-19) : under 0,5%
- Micro air intake filter : HEPA
- DEVICE CLASSIFICATION
- Protection class : Class I, Type BF, continuous operation
- Ingress of liquids : IPX0
- ALARMS : Power Failure Alarm, Fan Motor Alarm, Sensor Failure Alarm, Overheat Alarm, Deviation Alarm, Low Voltage Alarm, System Alarm
Customer reviews