Model MI-7000 - Microprocessor-controlled Screening Audiometer
The MI-7000 is a microprocessor-controlled screening audiometer designed specifically for use in industrial hearing conservation programs. Both flexible and easy to use, it can be programmed to meet the demands of very large-scale programs where extensive demographic data must be collected, stored, printed, and downloaded with threshold values to a computer database. Yet it can be quickly reprogrammed to allow the operator to press one button to start and print a completed test with no further data entry or control manipulations. Programmed options are battery-backed and remain in effect until changed by the operator. Tones are generated and controlled entirely by digital circuits, allowing the output levels of the MI-7000 to be adjusted through secured keyboard entry. The LCD display simultaneously shows all thresholds established for both ears as well as ongoing test conditions.
-
Most popular related searches
Benefits
- Versatile operation: Offers quick, one-button operation or large-scale testing with data export
- Small footprint: Built-in printer reduces space requirements
- Time-saving: Programmable operations streamline testing process
- Highly compatible: Works with numerous hearing conservation software packages
Features:
- Small, lightweight, and portable
- Fast, quiet, built-in printer
- Built-in talkover (automatic pause while in use)
- Test storage capability
- Numeric keypad for additional demographic/data entry
- Menu for setting programmable operations
- Complies with OSHA test requirements and qualifies as a microprocessor
- Allows for field calibration of output levels
- Wide operating voltage range, automatically adapts to both domestic and foreign supply
Testing features...
- Pause and resume capability
- Switch from automatic to manual as needed
- Start with either ear with option to test 8kHz
- Expanded attenuator range from -10 to 90 (selectable 0-90 dB range for compatibility with OSHA requirements)
- Error messages displayed on screen and in easily understood terms
- “Listening” test controlled by the patient response switch from inside the booth
- Adjustable audible alert for end-of-test and error conditions
Printouts include...
- Three-frequency-threshold averaging
- Time, date, and elapsed time of test
- Selected patient demographics
- Flagged manually determined thresholds
- Also, option to print current audiometer settings
Communications features...
- Serial port for external communication
- RS-232 data string compatible with popular output formats
- Compatible with numerous hearing conservation software packages