Model Reprodis Ce Hld4I - Disinfectant For Class Iib Medical Instruments / Devices
From Medical Device Cleaning and Disinfection
REPRODIS CE HLD4i Instrument Disinfectant is a new class of High Level Instrument Disinfectant which combines secure microbioligical credentials with safety in use and a comparatively rapid activity for the chemical reprocessing of surgical instruments, flexible or rigid endoscopes and devices. The product is primarily designed for open tank use but its unique flexibility renders it also suitable for other medical apparatus including ultrasonic baths.
Technology
MATERIALS COMPATIBILITY
- No adverse impact on metallic or non-metallic components of flexible endoscopes
- Non-damaging to electro-plating
- No adverse impact on dental products tested including amalgam
REPRODIS CE HLD4i will not harm sensitive instruments including flexible fibre optic instruments.
APPLICATIONS
To prepare 1 litre of REPRODIS HLD4i ready-to-use solution
and add 250ml of concentrate, for 15 litres use 750ml of concentrate and make up to level with water
- Prepare 950ml of water
- Add 50ml of REPRODIS CE HLD4i concentrate into 950ml of prepared water
- Stir gently to ensure mixing
- Larger quantities can be prepared using the same ratios, e.g. for 5 litres prepare 4750ml of water
Rigid endoscopes and other instruments/devices
- Immerse in proteolytic enzyme cleaner and wash clear of all debris
- Rinse thoroughly and dry
- Totally immerse in REPRODIS CE HLD4i Instrument Disinfectant for recommended time
- Remove and rinse in filtered or sterile water
- Dry and store in approved conditions
Flexible endoscope cleaning and disinfection
with disposable sponges or swabs and clean distal end with appropriate method
- Immerse disassembled endoscope in warm water andproteolytic enzyme cleaner. Wash the outside
- Remove valves, clean and disinfect in REPRODIS CE HLD4i Instrument Disinfectant for recommended contact time
- Brush clean the biopsy-suction channel
- Rinse all parts thoroughly and dry
- Totally immerse the scope in REPRODIS CE HLD4i Instrument Disinfectant for
- Rinse thoroughly with filtered or sterile water, as required
- Dry and store in approved conditions
- If the instrument is to be re-used immediately , purge all rinse water from the channels, dry
Microbiological
REPRODIS HLD4i has been tested effective against:
VIRUSESMurine Norovirus, Adenovirus, Hepatitis B, Herpes Simplex, HIV and Enveloped Viruses (incl Coronavirus SARS COV-2 in 2 minutes) and Bacteriophages
Mycobacterium avium and Mycobacterium terrae
YEAST AND FUNGICandida albicans and Trichophyton rubrum
BACTERICIDAL ACTIVITYEscherichia coli, Enterococcus hirae,Legionella pneumophila, Listeria monocytogenes, Methicillin Resistant Staphylococcus aureus, Methicillin Resistant Staphylococcus pseudintermedius, Pseudomonas aeruginosa, Salmonella tryphimurium and Staphylococcus aureus.
Health & Safety
REPRODIS CE HLD4I is manufactured in accordance with a Quality management System accredited to ISO13485
It displays none of the harmful characteristics of glutaraldehyde or PHMB based disinfectants and may safely be used as a direct substitute for these without air-conditioning. It is faster-acting, safer to use and more economic in use, disinfects in 10 mins. The non-oxidising formulation is safer for instruments than both peracetic acid and chlorine compound products.
Health and Safety Facts
- Non-sentitising
- Non-fuming
- Non-corrosive to instruments and devices
- Air conditioning not required
- Gloves and eye protection advised
Customer reviews
No reviews were found for Model Reprodis Ce Hld4I - Disinfectant For Class Iib Medical Instruments / Devices. Be the first to review!