Stimpod - Model NMS450X - Neuromuscular Monitor
Complete NMT Monitoring for Any Patient, Any Setting. Full Case NMT Monitoring enables safe extubation and eliminate residual paralysis in any hospital setting, provider preference and surgery type. Seamlessly integrate neuromuscular transmission data with anaesthesia monitors and EMR systems.
Details:
Save on your capital expenditure in the OR, PACU and ICU.
The only neuromuscular monitoring system available with both AMG and EMG enabling cost control at the point-of-care based on need and specific setting, allowing affordable standardisation across the entire hospital.
Choose either AMG or EMG modality at point-of-care for quick patient setup, providing 1st results in under a minute.
Full location versatility offers portable in-hand for bedside in the PACU or ICU and mountable options for complete OR intra-operative use.
The reusable AMG sensor is the most economical TOF monitor technology available.
Combining AMG with the single-use EMG electrode allows for an optimized Cost of Care model, enabling monitoring of all drug usage to ensure optimal use, thus saving on both paralytic and recovery agents.
AMG offers the most cost-effective option to implement with a reusable sensor and versatile patient setup options enabling neuromuscular transmission monitoring of the hand, toe or face.
EMG is ideally suited for neuromuscular monitoring of surgeries where tucked hands and arms are required, with optimised performance through a patented, skin-like electrode.
Technical Characteristics
Full case monitoring that performs setup verification for effortless depth of block monitoring. Auto adjusts stimulation intervals based on patients’ depth of block.
Stimulation ModesTrain-of-four (TOF), Post Tetanic Count (PTC), Full case monitoring (Auto), SupraMaximal Current (SMC), Double Burst (DB), Twitch (TWI) and Tetanus (TET)
Sensor DualityAuto-detects both AMG and EMG sensor technology.
Nerve Mapping and LocatingCombined mapping and location functionality to perform peripheral nerve blocks.
Technical Specifications
- Current Range
- Nerve Locating: 0.0 – 5.0mA
- Nerve Mapping: 0 – 20mA
- NMT Monitoring: 0 – 80mA
- Load Impedance
- Nerve Locating: 0 – 20kΩ (100V)
- Nerve Mapping: 0 – 20kΩ (400V)
- NMT Monitoring: 0 – 5kΩ (400V)
- Stimulating Modes
- Train-of-Four (TOF)
- Double Burst (DB)
- Post-Tetanic-Count (PTC)
- Supra Maximal Current (SMC)
- Tetanus (TET)
- Twitch (1Hz, 2Hz, 5Hz)
- Auto (Changes automatically depending on the depth of the block)
- Dimensions
- 145mm x 90mm x 30mm
- Operating Temperature
- 10 – 40° Celsius
- Storage Temperature
- 10 – 40° Celsius