Mectron Medical

Model PIEZOSURGERY Flex - Surgery Device

SHARE
PIEZOSURGERY® flex is an efficient, versatile and user-friendly device offering safety and precision in all situations.
Most popular related searches
THE RIGHT BALANCE BETWEEN POWER AND PRECISION
  • quick and effective cutting action
  • soft tissue protection
  • improved intra-operative control and surgical sensitivity
  • maximum flexibility in designing osteotomic lines
HIGH-QUALITY SURGICAL INSERTS
  • thinner, more precise osteotomies
  • minimal bone sacrifice along the whole depth of cut

 DESIGNED TO OPEN A NEW ERA IN BONE SURGERY

PIEZOSURGERY® opened a new era of bone surgery thanks to ultrasonic micro-vibrations.

INTRAOPERATIVE ADVANTAGES
  • Selective cut          

micro-vibrations generate an effective cutting action on mineralized tissue, reducing the risk of soft tissue damage

  • Micrometric cut

micro-vibrations allow perfect control of the cutting action, resulting in maximum precision and minimal bone sacrifice

  • Cavitation effect

the cavitation effect reduces the risk of bone necrosis and helps create a blood-free field

POSTOPERATIVE BENEFITS
  • Healing                  

ultrasonic micro-vibrations reduce inflammatory cells on the bone surface and promote osteoblast production, promoting quicker healing and an improved postoperative outcome

SCIENTIFIC STUDIES

Comparative studies have demonstrated both the intraoperative advantages and postoperative benefits of the PIEZOSURGERY® device.

OSSEOINTEGRATION

The inflammatory cells were more numerous in samples obtained from the drilled sites (Fig. 1). Neo-osteogenesis was quantified by considering the absolute number of osteoblasts per high-power field (mean of 10 fields) in osteo-genetic areas; it was consistently more active in the bone samples from the implant sites prepared using the piezoelectric bone surgery technique (Fig. 2).

Preti G., Martinasso G., Peirone B., Navone R., Manzella C., Muzio G., Canuto R.A., Schierano G. "Cytokines and Growth Factors Involved the Osseointegration of Oral Titanium Implants Positioned using Piezoelectric Bone Surgery versus a Drill Technique: a Pilot Study in Minipigs." J Periodontol. 2007 Apr; 78(4):716-22

POSTOPERATIVE PAIN

In the group A, the lower post-operative pain highlights the absence of a thermal effect on the surface cut and shows a better healing process.

Crippa B., Salzano F.A., Mora R., Dellepiane M., Salami A., Guastini L. "Comparison of postoperative pain: piezoelectric device versus microdrill" Eur Arch Otorhinolaryngol. 2011 Feb 16 [Epub ahead of print]

DESIGNED TO BE EFFECTIVE

Mectron`s PIEZOSURGERY® technology guarantees cutting effectiveness.

  • MODE SETTING: offers the best surgical performance for each insert.
  • FEEDBACK SYSTEM: automatically monitos and adjusts the tuning of the vibration frequency for each insert.