Diaton - Tonometer
Innovative Diaton Tonometer provides high reliability of IOP results and makes it possible to diagnose glaucoma on the early stage and appoint necessary treatment and medicines for adult as well as pediatric population. The unique methodology of intraocular pressure (IOP) measuring through the eyelid and sclera applied in the device provides new resources in ocular tonometry, simplicity and safety of tests.
- Quick and painless screening examinations of adult or pediatric patients
- Safe tonometry – No contact with mucous membrane or cornea; No Risk of Infecting
- IOP control during selection of adequate medicines
- IOP measuring in the presence of chronic conjunctivitis, corneal erosion, edema and cornea dimness
- IOP measuring in patients after corneal surgeries
- Intraocular pressure monitoring (diurnal tension curve)
- IOP measuring in immobilized patients and in children
- IOP measuring during contact correction (contact lenses or scleral lenses are not taken out).
- Tonometer Diaton is the perfect solution in the following cases when the use of other tonometry devices is problematic or impossible: Keratitis, Conjunctivitis, Keratotone, Cornea Dimness, Keratoprosthesis, Keratoplastics, LASIK, LASEK, PRK, Astigmatism, Ametropy, etc.,
Diaton Tonometer is intended for use by Ophthalmologists, Optometrists, Ophthalmic technicians as well as Inpatient & Outpatient Clinics such as Hospitals, Emergency Rooms, Urgent Care Clinics, Nursing & Elderly Homes, General & Specialty Practitioners.
Measurement range, mm Hg: 5-60
Measurement error: Limit of the admissible measurement error in the range, not more:
from 5 to 20 mm Hg - ±2 mm Hg;
from 20 to 60 mm Hg - ±10%
The time of a single measurement, s, not more: 3
Supply voltage, V: 3
Number of measurements using one battery set, not less: 1500
Service life, not less: 8
Weight, g: 89
Dimensions, mm, not more: 174 x 26 x 20
- Safe Tonometry = No Risk of Infecting. No Contact with Mucous Membrane or Cornea (safer vs other contact or noncontact tonometers) Infection Prevention Tonometry Solution
- Measure IOP THROUGH Eyelid and Sclera (No contact with eyeball or the cornea, IOP independent of CCT)
- Quick, Puff-free & Painless (Perfect for children and squeamish adults)
- No need for Sterilization (contact only with eyelid. Meets and Exceeds JCAHO Joint Commission Sterilization and Disinfection Standards)
- Enables to Measure Accurate IOP even with Contact Lenses or with Scleral Lenses ON (Only with Diaton)
- Can Accurately measure IOP in sitting or supine position. (no special set up or ophthalmic chair needed)
- Social Distancing & Tonometry Compliance – Diaton user can stand on the Side of the patient vs in Front (at arm’s length, away from the line of breath or cough)
- No Rubber Covers, Plastic Tips or Proparacaine (Latex-free, Green, Cost Efficient)
- No Calibration Diaton is pre-calibrated by design. Ready-to-use. (saves time and efforts)
- No Pachymetry (CCT) adjustments needed for Diaton tonometry variability of Central Corneal Thickness (CCT) may greatly affect corneal tonometry device results in either direction. IOP results with Diaton tonometer are completely independent of thin or thick corneal biometrics as IOP with Diaton is measured via Sclera and not via Cornea as all other tonometers (No need to purchase a pachymeter, saves time and efforts)
- Easy to use. Can be used by any trained personnel (easy to follow step-by-step video instructions in 5 languages)
- Complimentary 2-way video training Saves time on staff training, includes helpful tips and best practices.
++Handheld, non-contact, portable, digital, pen-like tonometer++