ExothermeTranscutaneous Vascular Laser System

SHARE

Exotherme is a transcutaneous vascular laser, dedicated to spider veins and telangiectasias, up to 2mm of diameter, for a safe, efficient and painless treatment. The principle of the Exotherme laser is based on the thermal action of the laser. The transcutaneous irradiation (with a penetration of 1 to 2 mm in the tissue) causes tissue selective absorption by hemeglobin (hemoglobin is the main target of the laser).


Most popular related searches

The effect of selective photocoagulation is based on two effects:

  • Conversion of light energy into heat,
  • Coagulation of the vascular wall with collagen denaturation.

Selective photocoagulation does not cause purpura (contrary to photothermolysis).

The superficial vessels, from 0.2 to 2 mm of diameter.

  • Spider veins
  • Telangectasias

Exotherme™ is cleared on the US market for the photocoaguation of leg telangiecatasias.  

The auto-regulated cooling system allows to:

  • protect the epidermis
  • make the treatment painless
  • use higher fluencies
  • make the treatment reproducible without discomfort for the patient
    cause no inflammatory reaction

The built-in camera allows:

  • on screen visualization
  • to target more precisely
  • to control the dosimetry (spasm of the vein)
  • the patients to watch their treatments in real time
  • to give value to the act because the patient see the immediate effects of the laser.

The Multipulse Mode:

  • More efficiency of the laser
  • Reduction of the energy of the laser by a factory of 3 to 4
  • Increased safety for surrounding tissue

A combination of efficient techniques:

  • On-screen visualization of the treatment
  • Optical zoom x10
  • Auto-regulated cooling system
  • Multipulse Mode

Multipulse Mode: Special sequence of laser shots:

  • The 1st pulse increases the absorption of the blood. (absorption is multiplied by 3 – 4) → Selective absorption
  • 2nd and 3rd pulses: maintain the elevation of temperature in the vessel.
  • Laser: Diode Laser
  • Wavelenght: 980 nm +/- 10
  • Power: 25 Watts
  • Cooling system: Peltier and Air
  • Emission mode: Pulsed - Multipulse
  • Device class: lib
  • Aiming beam: Diode Laser
  • Wavelenght: 635 nm +/- 20
  • Power: < 2 mWatts
  • Laser class: 3R
  • Power supply: 110-240 VAC; 50 to 60 Hz
  • Weight: 15 kg
  • Dimensions: 45 x 45 x 35 cm
  • Certifications: FDA cleared - CE 1639