Emergent -Model VIGIV - CNJ-016 -Vaccinia Immune Globulin Intravenous
Blood glucose measurement in patients receiving VIGIV must be done with a glucose-specific method (monitor and test strips) to avoid interference by maltose contained in VIGIV. Glucose dehydrogenase pyrroloquinolinequinone (GDH-PQQ) or glucose-dye-oxidoreductase method (monitor and test strips) must not be used for blood glucose testing in patients receiving VIGIV, since maltose in IGIV products has been shown to give falsely high blood glucose levels in these testing systems. This could result in the inappropriate administration of insulin, resulting in life-threatening hypoglycemia. Cases of true hypoglycemia may go untreated if the hypoglycemic state is masked by falsely elevated glucose readings.Carefully review t he product information of the blood glucose testing system, including that of the test strips, to determine if the system is appropriate for use with maltose-containing parenteral products [see 5.3 Blood Glucose Monitoring].