Basda -Model BTI-050 -Wide Open C Shape 0.5 Tesla Permanent Magnet MRI Machine
0.5T MRI Machine Wide Open C-Shape Permanent MR 0.5 Tesla Magnetic Resonance MR Diagnostic medical Imaging.
- Shape:Open MRI
- Material:Magnet
- Magnetic Field:0.5T
- RF System Type:Digital Transmit And Receive
- Gradient:Self Shielding
- Shielding:Copper
Product Details:
- Place of Origin: Guangdong, P.R.C.
- Brand Name: Basda Medical
- Certification: CE, ISO13485
- Model Number: BTI-050
Payment & Shipping Terms:
- Minimum Order Quantity: 1 Set
- Price: USD 800,000-1,000,000
- Packaging Details: 1 unit/wooden box, international export packing
- Delivery Time: 30-45 Days
- Payment Terms: Credit card, Paypal, T/T, Western Union, MoneyGram
- Supply Ability: 200 Machines per Year
Much open and comfort
More patient comfort and more space for surgery. Affinity C-shape magnets, creating a maximum of openness, offer a maximum vision for patients, especially leave much space comfort for obese patients, minimizing claustrophobia of patients and providing more space for MR intervention surgery.
Very good gradient system
Gradient system helps to provide higher resolution pictures, BTI-050 gradient system(X,Y,Z) gradient intensity is 25mT/m,Higher the gradient intensity, faster imaging speed, shorter of scanning time; Higher the gradient intensity, thinner of imaging slice, higher of image resolution
The new technology
4D shimming:
Use of advanced active shimming algorithm for real-time automatic shimming on each examination to ensure the magnetic field always maintain the highest uniformity. Magnetic field homogeneity and stability of the MRI images always are the most important guarantee of the high-resolution, high SNR and high contrast. They are the important indicators of the level of magnet design, the better the smaller the value, directly determines the SNR of the image, like a car chassis, stability is essential, the magnetic field uniformity is maintained at
Eddy Zero Technology:
- Magnet design uses breakthrough anti-eddy current technology
- The gradient coil using self-shielded active anti - eddy current technology
- Implementation of precision eddy current compensation algorithm, completely eliminate the impact of eddy current
- The eddy current because of the high gradient and high slew rate come from ultra-fast sequence was resolved completely, which guarantee to get the best clinic image
Advanced RF System
- Fast 4 channels RF system
- All phased array coils provide best SNR pictures.