Athroplasty Articles
-
COREX Case Studies
Explore how surgeons are using COREX to harvest cancellous bone graft using a minimally invasive ...
-
Surgical Site Infection: Methods of Prevention & Tools for Predicting Risk - Case Study
Medical History A 55-year-old white male has degenerative arthritis of the knees. 10 months ago, the patient underwent total knee replacement on the left knee without complication. The surgical incisions had closed without signs of surgical site infection. At the time, he made a good recovery. He is fully functional and fully independent. Patient is a chain smoker with a wife and two children. He ...
-
A New Concept of Mosaicplasty: Autologous Osteoperiosteal Cylinder Graft Covered With Cellularized Scaffold
Abstract: A concern regarding osteochondral autograft transfer for chondral defects is donor-site morbidity of the knee, the most common source of the autograft. To avoid the drawbacks of osteochondral autograft transfer, a cylindrical osteoperiosteal graft harvested from the iliac crest covered by a same-sized cylinder of hyaluronic acidebased polymer scaffold pretreated with bone marrow ...
-
Surgeon Testimonials for the Archer CSR Total Shoulder System - Case Study
Below are several case studies and testimonials from actual surgeons performing total shoulder arthroplasties using the Archer™ CSR Total Shoulder System. The utilization of the anatomic Archer CSR humeral implant a/lowed for adequate bone stock retention to complete an anatomic transosseous supraspinatus repair and remove all of the patients painful pathology in one procedure. The patient ...
-
Surgeon Testimonials for the Archer CSR Total Shoulder System - Case Study
For this procedure I used Catalyst's Archer CSR system for a total shoulder arthroplasty using a lesser tuberosity osteotomy repair with a screw-and-suture technique. Post operatively this patient did very well. He had return of full range of motion at 12 weeks. He was able to return to all his activities, including sporting activities as well as lifting, pushing and ...
-
Lower Extremity Amputations: Why, What Kind, & Life After
Every year, surgeons perform a lower-limb amputation due specifically to diabetes on approximately 73,000 patients in the US alone. Annually there are over 1 million limb amputations worldwide. Most of these amputations are performed for the treatment of non-healing diabetic foot ulcers that resulted from PAD (Peripheral Arterial Disease). These non-healing foot ulcers are caused by high blood ...
By EO2 Concepts
-
Intellijoint KNEE: How It Began to Where It is Now
Intellijoint Surgical is proud to announce a new, optional feature to the Intellijoint KNEE system. It helps provide quantitative measurements of femoral and tibial rotational alignment. Originally released back in 2020, Intellijoint KNEE is the second application following the company’s flagship product, Intellijoint HIP. The Intellijoint team has continued to innovate and expand ...
-
Long-Term Outcomes Following Lumbar Nucleus Replacement
Abstract Background Nucleus replacement devices are designed to replace the native pain-generating lumbar nucleus while preserving the annulus fibrosus, endplates, and natural motion. The DASCOR Disc Arthroplasty Device seemed to perform well clinically but was discontinued in 2009. While there are no commercially available NRDs today, the potential advantages of using such devices have ...
-
Value-Based Robotics, Pt.4: Micromate™ - Bringing Usability To The Operating Room
Our Value-Based Robotics series advances towards the actual clinical use of robotics and issues concerning practicality and surgeon onboarding and training. It is generally accepted that robotic surgical systems enable minimally invasive surgery and improve outcomes, including shorter recovery times, less scarring, and reduced healthcare costs. This being said, the jury is still out on whether ...
-
New Manuscript: Manipulation Rate is Not Increased After Customized Total Knee Arthroplasty - Case Study
Background Manipulation under anesthesia (MUA) is a standard treatment for arthrofibrosis after total knee arthroplasty (TKA), with reported rates of 1.5-6%. Customized TKA may have better outcomes by matching individual patient anatomy. However, a previous study reported an unacceptably high rate of MUA for customized TKAs. This study reports the incidence of MUA in a large cohort of second ...
By Conformis
-
Failure causes in hip resurfacing arthroplasty – retrieval analysis
Metal–on–metal hip resurfacing arthroplasty represents an alternative treatment option for young and active patients with osteoarthritis. The advantages of metal–on–metal hip resurfacing arthroplasty include lower wear rate, restoration of anatomic hip biomechanics, preservation of bone stock for subsequent revision procedures, and enhanced stability due to the larger diameter of articulation. ...
-
Part 1: In-vitro release of gentamicinpalmitate coating in uncemented titanium implants
Microporous surfaces of commercially available uncemented Tilastan® implants were coated with gentamicinpalmitate. The roughness of the titanium implant surfaces remained largely intact. During the first few days, the gentamicin release was comparable to the elution of this antibiotic from commercially available PMMA bone cements. Compared to PMMA cements, the implants coated with the ...
-
Bone cement: an overview
Polymethylmethacrylate bone cement is a widely utilised material in the field of orthopaedic surgery and specifically total joint arthroplasty. Despite this, its mechanical properties are poorly understood by the end-user and there is controversy over the manner in which the material should be tested and the effects some commonly used techniques have on its mechanical properties. This article ...
-
An autonomically-healed PMMA bone cement: influence of the crystal size of Grubbs' catalyst on fracture toughness and polymerisation rate
In this study, it was shown that the concept of autonomic healing of a neat polymeric material, which was introduced by White et al. (2001) could be applied to poly methyl methacrylate (PMMA) bone cement. The bone cement brand used – Surgical Simplex®P – is one that is widely used in cemented arthroplasties; the healing agent used was 2.0 wt.% dicyclopentadiene (DCPD), encapsulated in poly ...
Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you