These materials offer reduced wear rates and improved implant performance, resulting in prolonged implant life. Implant Design Optimization: Persistent research and technological advancements have led to optimized designs of bipolar hip prostheses, emphasizing optimal stability, range of motion, and biomechanics. ...
The novel nucleus replacement device resulted in similar compressive displacement, endplate stress, and annulus stress and slightly higher reaction moment compared with the normal nucleus. The solid implant resulted in decreased displacement, increased endplate stress, decreased annulus stress, and decreased reaction moment compared with the ...
Periodontal Surgery Lasers are beneficial in reducing traditional surgical problems such as bleeding, reduced vision, pain, scarring, suturing, bacteremia, long healing period and wound contraction. They will also result in higher patient acceptance, since no or little anesthesia is required. ...
ByPIOON
Methods A retrospective review of hospital records from a single institution was performed to identify all patients that underwent implantation of a DASCOR device between 2006 and 2009. Clinical outcome and imaging data were gathered to assess device performance of the DASCOR device over an extended period of time. ...
Background Manipulation under anesthesia (MUA) is a standard treatment for arthrofibrosis after total knee arthroplasty (TKA), with reported rates of 1.5-6%. Customized TKA may have better outcomes by matching individual patient anatomy. However, a previous study reported an unacceptably high rate of MUA for customized TKAs. This study reports the incidence of MUA in a large cohort of second ...
The use of a novel implantable string subcutaneous defibrillator (ISSD, Newpace) that has no can, and has been designed to be placed without the need for a surgical pocket, may allow improved patient compliance and aesthetics, is less invasive, and has optimal implantation time. ...
In order to determine the behaviour and location of transplanted human adipose derived stem cells, the QDs labelled stem cells are implanted by local injection at thoracic 8 spinal cord in rats in this study. The expression of QDs in adult rats is evaluated at 2 hours, 1, 7 and 14 days after implantation. The results show the QDs labelled human ...
We discuss the fabrication of flexible implantable probes for recording neuronal activity in the rat brain. We fabricated such probes bearing 12 platinum electrodes, using polyimide as a substrate and SU–8 as an insulation layer. ...