Centinel Spine
- Home
- Companies
- Centinel Spine
- Products
- Prodisc - Model C - Anterior Cervical ...
Prodisc - Model C - Anterior Cervical Total Disc Replacement
FromCentinel Spine
The most studied and clinically-proven total disc replacement technology in the world.
Most popular related searches
cervical disc replacement
cervical disc
physiological range
cervical spine
cervical anterior
vertebral segment
anterior spine
soft tissue
vertebral body
replacement surgery
The Most Studied TDR System in the World
Beginning with clinical usage in 1990, the prodisc design has been validated with over 125,000 device implantations worldwide and more than 540 published papers. 1Determined Safe & Effective
for Intractable SCDD
The prodisc C Total Disc Replacement has been determined to be safe and effective in the treatment of intractable symptomatic cervical disc disease (SCDD) at one level from C3 to C7.for Intractable SCDD
The prodiscC Total Disc Replacement surgery is intended to:
- Remove the diseased disc
- Restore normal disc height
- Decompress surrounding neural structures
- Potentially provide motion in affected vertebral segment
- Improve patient function
Design Philosophy
The prodiscC implant has been designed to maintain the physiologic range of motion in the spine. The implant was developed using the clinically proven ball and socket concept used in joint replacement implants for over 40 years. The prodiscC implant is composed of three components – two cobalt chrome alloy (CoCrMo) endplates and an ultra-high molecular weight polyethylene (UHMWPE) inlay and is inserted into the vertebral bodies en-bloc.
Mechanism of Action
The prodiscimplant is a ball and socket design with a fixed center of rotation. This patented design has been in clinical use since 1990 and utilized across the entire product platform. The fixed center of rotation allows physiological range of motion while providing stability to the spine and significantly reducing reoperations at the adjacent levels.
Secure Fixation with No Profile
- Patented central keel provides secure primary fixation
- Plasma-sprayed titanium surface on bone contacting surfaces promotes integration and increases stability
- Implant does not contact anterior soft tissue structures after implantation
Anatomical Sizing
- 18 anatomical sizes facilitate an accurate match with the patient’s anatomy
- 6 footprints
- 3 heights (5, 6 and 7 mm)
Safe and Reproducible Surgical Technique
Working with leading spine surgeons from around the world, the prodiscC instrumentation and surgical technique has been refined to facilitate safe and reproducible implantation through a standard transverse approach to the anterior cervical spine.
• Three step implantation technique • Enables accurate sizing and precise placement of the implant
1. Trial
2. Chisel
3. Implant
4. Final
Streamlined Instrumentation
- Designed for standard transverse approach to the anterior cervical spine
- Enables clear visualization into the disc space